This is an unedited manuscript accepted for publication and provided as an Article in Press for early access at the author’s request. The article will undergo copyediting, typesetting, and galley proof review before final publication. Please be aware that errors may be identified during production that could affect the content. All legal disclaimers of the journal apply.
Anshul Agrawal,
Manvendra Verma,
Ajay Kumar,
- Lecturer, Department of Civil Engineering, GLA University Mathura, Uttar Pradesh, India
- Assistant Professor, Department of Civil Engineering, GLA University Mathura, Uttar Pradesh, India
- Lecturer, Department of Civil Engineering, GLA University Mathura, Uttar Pradesh, India
Abstract
Base isolation technique has become most popular that improves resistant quality during a seismic earthquake. These bases seclude moves under high pressure and they soak up an earth tremor smash by minimizing oscillating and trembling of ground. Adaptive base solitude system includes the separation system is Lead Rubber Bearing, Friction Isolators, channel Method, Laminated Rubber Bearing. Base separation is the broadly accepted seismic protected skeleton employed in any edifice in Earth tremor protectorate. Ground isolation techniques help structure to separate their super and sub structure thereby reducing the destruction during earthquakes. This Paper studied G+8 symmetrical building fabricates of materials like Reinforced cement concrete, Bracings of steel with (LRB) Lead Rubber Bearing and (FPB) Friction Pendulum Bearing by Response spectrum method in SAP-2000 software. In order to discuss the performances of modal time-period, ground base-shear, and joint-displacements are measured and difference is discussed. This can be negotiated that its far preferable to give seclude systems in tremulous regions in preference to fixed joint base and the performance of both Friction isolator and Rubber isolators for the structure is slightly different and as far as concern to modal time period it is observed that LRB isolated structure has slightly less modal period than FRB isolated structure.
Keywords: RCC, Response spectrum, Fixed, Lead Rubber Bearing, Friction Pendulum Bearing, Base isolation structures, SAP-2000
[This article belongs to Special Issue under section in Journal of Polymer and Composites (jopc)]
Anshul Agrawal, Manvendra Verma, Ajay Kumar. Comparative Analysis of using Rubber isolator and Friction isolator in G+8 Building by SAP 2000. Journal of Polymer and Composites. 2024; 13(01):479-487.
Anshul Agrawal, Manvendra Verma, Ajay Kumar. Comparative Analysis of using Rubber isolator and Friction isolator in G+8 Building by SAP 2000. Journal of Polymer and Composites. 2024; 13(01):479-487. Available from: https://journals.stmjournals.com/jopc/article=2024/view=190065
Browse Figures
References
- Naidoo P, Drosopoulos G. Evaluation of the dynamic response of structures using auxetic-type base isolation. Frat ed Integrita Strutt. 2020;14(51).
- Verma A, Gupta A, Nath B. Base Isolation System: A Review. Int J Eng Sci Invent. 2017;6(9).
- Nigam M, Verma M. Effect of Nano-Silica on the Fresh and Mechanical Properties of Conventional Concrete. Forces Mech [Internet]. 2023;10(22):100165. Available from: https://doi.org/10.1016/j.finmec.2022.100165
- Somasekharaiah HM, Dharmesh EN, Ghouse M. A Comparative Study on RC Frame Structure Considering Lead Rubber Bearing and Triple Friction Pendulum Bearing. Artic Int J Innov Res Sci Eng Technol. 2016;3297:14907–18.
- Sheikh H, Van Engelen NC, Ruparathna R. A review of base isolation systems with adaptive characteristics. Vol. 38, Structures. 2022.
- De Luca A, Guidi LG. State of art in the worldwide evolution of base isolation design. Soil Dyn Earthq Eng. 2019;125.
- Abé M, Fujino Y, Yoshida J. Seismic Performance Evaluation of Base-Isolated Bridges. IFAC Proc Vol. 1998 Sep;31(28):117–21.
- Mohammad Z, Bilal A, Baqi A. Effect of Base Isolation on the Seismic Performance of Hill Buildings. In: Lecture Notes in Civil Engineering. Springer Science and Business Media Deutschland GmbH; 2022. p. 229–40.
- Qahir Darwish A, Bhandari M. Seismic response reduction of high rise steel-concrete composite buildings equipped with base isolation system. Mater Today Proc. 2022;59.
- Singh H, Kumar Tiwary A. Dynamic analysis of RCC framed structure considering effect of viscous dampers and base isolation. Mater Today Proc. 2022;
- Nuraini S, Tambusay A, Suprobo P. A comparative study of base isolation devices in light rail transit structure featured with lead rubber bearing and friction pendulum system. In: MATEC Web of Conferences. EDP Sciences; 2018.
- Sharma U, Gupta N, Verma M. Prediction of Compressive Strength of Geopolymer Concrete using Artificial Neural Network. Asian J Civ Eng [Internet]. 2023;24(8):2837–2850. Available from:https://doi.org/10.1007/s42107-023-00678-2
- Sharma U, Gupta N, Verma M. Prediction of compressive strength of GGBFS and Flyash-based geopolymer composite by linear regression, lasso regression, and ridge regression. Asian J Civ Eng [Internet]. 2023;24(8):3399–3411. Available from: https://doi.org/10.1007/s42107-023-00721-2
- Upreti K, Verma M, Agrawal M, Garg J, Kaushik R, Agrawal C, et al. Prediction of Mechanical Strength by Using an Artificial Neural Network and Random Forest Algorithm. J Nanomater. 2022;2022:1–12.
- Dai K, Yang Y, Li T, Ge Q, Wang J, Wang B, et al. Seismic analysis of a base-isolated reinforced concrete frame using high damping rubber bearings considering hardening characteristics and bidirectional coupling effect. Structures. 2022 Dec;46:698–712.
- Subramani T, Shanmuganandam M. Multistorey residential building with base isolation method using SAP. Int J Eng Technol. 2018;7(3).
- Ghodke RB, Admane S V. Effect Of Base-Isolation For Building Structures. Int J Sci Eng Technol Res. 2015;4(4):971–4.
- Wen J, Li X, Xie Q. Cost-effectiveness of base isolation for large transformers in areas of high seismic intensity. Struct Infrastruct Eng. 2022;18(6).
- Upreti K, Verma M. Prediction of compressive strength of high-volume fly ash concrete using artificial neural network. J Eng Res Appl. 2022;1(2):24–32.
- Arathy S, Manju PM. Analysis of friction pendulum bearing isolated structure. Int Res J Eng Technol. 2016;317–22.
- Losanno D, Ravichandran N, Parisi F, Calabrese A, Serino G. Seismic performance of a Low-Cost base isolation system for unreinforced brick Masonry buildings in developing countries. Soil Dyn Earthq Eng. 2021;141.
- Majage SC, Phadatare PNP. Design of high damping rubber Isolator for RC Multistoried Structures and its Comparative Seismic Analysis. 2018;553–8.
- Hu GJ, Ye K, Tang ZY. Design and analysis of LRB base-isolated building structure for multilevel performance targets. Structures. 2023;57.
- Verma M, Nigam M. Effect of FRP on the Strength of Geopolymer Concrete. AIP Conf Proc. 2023;2721(1):020030.
- Verma M, Nigam M. Experimental Investigation on the Properties of Geopolymer Concrete after Replacement of River Sand with the M-Sand. AIP Conf Proc. 2023;2721(1):020029.
- Verma M, Nigam M. Investigation on the Effect of Curing Time on the Mechanical Properties of Geopolymer Concrete. AIP Conf Proc. 2023;2721(1):020031.
- Chouksey A, Verma M, Dev N, Rahman I, Upreti K. An investigation on the effect of curing conditions on the mechanical and microstructural properties of the geopolymer concrete. Mater Res Express [Internet]. 2022;9(5):55003. Available from: http://dx.doi.org/10.1088/2053-1591/ac6be0
- Verma M, Yadav SK. Construction and Demolition Waste Utilisation as Recycled Concrete Aggregate in Concrete: A State of Art. J Eng Res Appl. 2023;02(02):31–5.
- Jayanthi N, Ghosh T, Meena RK, Verma M. Length and width of low‑light, concrete hairline crack detection.pdf. Asian J Civ Eng. 2024;25(3):2705–2714.
Journal of Polymer and Composites
Volume | 13 |
Special Issue | 01 |
Received | 23/04/2024 |
Accepted | 24/06/2024 |
Published | 18/12/2024 |